Juris Ormanis
Mg. sc. ing
Elektronikas inžinieris
Projekti
11 rezultāti
- Kiberfizikālo sistēmu tehnoloģiju attīstība un to pielietojumi medicīnā un viedā transporta jomā (KiFiS) Noslēgts
- Droša elektroenerģijas padeves atslēgšana industriālām piedziņas sistēmām (R-PODID) 01.09.2023. – 31.08.2026. Noslēgts
- Uzlabot skaitļošanas iekārtas darbības efektivitāti, uzticamību un pielāgojamību dažādiem ekspluatācijas apstākļiem (LMT BOX) 01.11.2025. – 30.06.2026. Noslēgts
- Ilgtspējīga un zaļa elektronika cirkulārai ekonomikai (Sustronics) 01.06.2023. – 31.05.2026. Noslēgts
- Iespējamo LTE-M un NB-IoT komunikācijas sistēmu uz moduļu pamata (SoM) ekspluatācijas un darbības režīmu izpēte dažādu enerģijas avotu pielietojuma gadījumā 05.01.2025. – 31.12.2025. Noslēgts
Publikācijas
- 2026
Ambient Temperature Impact on the Thermal Behavior and Power Consumption of the NVIDIA Jetson AGX Orin in an Outdoor Enclosure(atveras jaunā logā)
Rihards Krišlauks, Deniss Tiscenko, Vladislavs Medvedevs, Juris Ormanis, Janis Judvaitis.
Electronics, Sēj. 15 (11), MDPI
Kopsavilkums
<p>This paper presents a thermal and power characterization of the NVIDIA Jetson AGX Orin deployed in a realistic outdoor edge AI enclosure, integrated with power supplies, a Long Term Evolution (LTE) module, and a thermostat-controlled fan, across an ambient temperature range from −20 °C to +40 °C. The device was tested in a climate chamber under two workloads: a synthetic CPU and GPU stress test, and a YOLOv8s inference workload (TensorRT FP16, 640 × 640 input). Internal temperatures were recorded using four calibrated platinum Resistance Temperature Detectors (RTD)—PT100/PT1000, while Jetson chip temperatures and power consumption were logged via tegrastats and jtop. At sub-zero ambient temperatures, heat dissipated by the device itself kept all components within their operating ranges down to −20 °C. At the +40 °C setpoint, the stress test triggered Jetson thermal throttling at GPU and CPU temperatures of +95.6 °C and +99.0 °C, respectively. Under the same conditions, the YOLOv8s inference workload sustained 108.8 frames per second (FPS) at 19.1 W average power, approximately half of the 36.5 W consumed under the stress test, with chip temperatures well below the throttling threshold. These findings indicate that synthetic stress tests substantially overestimate the thermal and power demands of the tested inference workload, and that the enclosure retains sufficient thermal headroom for outdoor edge device deployment.</p>
Indeksēts Scopus / WoS · Scopus procentile: 83
- 2025
Experimental Evaluation of NB-IoT Power Consumption and Energy Source Feasibility for Long-Term IoT Deployments
Valters Skrastiņš, Vladislavs Medvedevs, Dmitrijs Orlovs, Juris Ormanis, Janis Judvaitis
IoT (ISSN 2624-831X), MDPI
Kopsavilkums
Narrowband Internet of Things (NB-IoT) is widely used for connecting low-power devices that must operate for years without maintenance. To design reliable systems, it is essential to understand how much energy these devices consume under different conditions and which power sources can support long lifetimes. This study presents a detailed experimental evaluation of NB-IoT power consumption using a commercial System-on-Module (LMT-SoM). We measured various transmissions across different payload sizes, signal strengths, and temperatures. The results show that sending larger packets is far more efficient: a 1280-byte message requires about 7 times less energy per bit than an 80-byte message. However, standby currents varied widely between devices, from 6.7 µA to 23 µA, which has a major impact on battery life. Alongside these experiments, we compared different power sources for a 5-year deployment. Alkaline and lithium-thionyl chloride batteries were the most cost-effective solutions for indoor use, while solar panels combined with supercapacitors provided a sustainable option for outdoor applications. These findings offer practical guidance for engineers and researchers to design NB-IoT devices that balance energy efficiency, cost, and sustainability.
Indeksēts Scopus / WoS
- 2024
Precise realtime current consumption measurement in IoT TestBed(atveras jaunā logā)
Rihards Balass, Vladislavs Medvedevs, Andris Ivars Mackus, Juris Ormanis, Armands Ancans, Janis Judvaitis
Open Research Europe, Sēj. 3 (7), Taylor & Francis
Kopsavilkums
Background The Internet of Things, similar to wireless sensor networks, has been integrated into the daily life of almost everyone. These wearable, stationary, or mobile devices are in multiple locations, collecting data or monitoring and executing certain tasks. Some can monitor environmental values and interact with the environment, while others are used for data collection, entertainment, or even lifesaving. To achieve the wireless part of the system, the majority of sensor nodes are designed to be battery-powered. While battery power has become increasingly ubiquitous, it tends to increase the global carbon footprint of electronic devices. This issue can be mitigated by employing some form of energy harvesting so that batteries can be refilled and the gadget lasts longer, but this does not alter the reality that batteries are still used and eventually discarded. Methods In this paper, the authors emphasize the significance of power consumption in battery-powered devices. To be able to monitor devices’ power consumption, one of the measurable parameters is current. When users know the exact current consumption, they can decrease it by polishing the program or tweaking the duty cycle, making radio transmit fewer data or less frequently, thus decreasing overall power draw. Results In order to simplify current consumption monitoring, the authors have developed a testbed facility that provides real-time current consumption measurements, which may be used to enhance the duty cycle and battery life of the aforementioned devices. Conclusions While minimizing total current consumption is a great way to extend the battery life and, thus, the carbon footprint, the primary culprit in the Internet of Things is radio communications. This transmission is the primary source of current consumption. By determining the exact amount of current drawn during transmission and adjusting it, users can significantly extend battery life.
Indeksēts Scopus / WoS · Scopus procentile: 58
- 2024
Electrodes for bio-electrical impedance and body-coupled communication
Juris Ormanis, Anastasija Sevcenko, Vladislavs Medvedevs, Krisjanis Nesenbergs, Armands Ancans, Modris Greitans
MeMeA 2024, The 19th edition of the IEEE International Symposium on Medical Measurements and Applications, IEEE
Kopsavilkums
In the pursuit of enhancing healthcare through biomedical engineering and wearable technology, this research conducts a thorough investigation into the efficacy of different electrodes for BioZ and BCC applications. We meticulously analyze Ag/AgCl, EMS, and gold-plated electrodes across a variety of metrics such as SNR, Settling Time, and CER. Through a series of experiments tailored to assess their performance in monitoring heart rate, breathing, and facilitating data transmission through the human body, we uncover the specific contexts in which each electrode type excels. This study highlights the critical role of electrode choice in advancing non-invasive diagnostic methods through wearable technology. It provides a comprehensive comparison of various electrode types, highlighting their respective benefits for specific health monitoring applications. This research aims to guide the future development of wearable devices, aiming for an optimal balance between sustainability, accuracy, and user convenience in electrode selection for BioZ measurement and BCC applications. This study highlights the critical role of electrode choice in advancing non-invasive diagnostic methods through wearable technology. It provides a comprehensive comparison of various electrode types, highlighting their respective benefits for specific health monitoring applications. This research aims to guide the future development of wearable devices, aiming for an optimal balance between sustainability, accuracy, and user convenience in electrode selection for \gls{BioZ} measurement and \gls{BCC} applications.
Indeksēts Scopus / WoS
- 2023
BEAM: Body Coupled Communication Enabled Amplitude Modulation for Skinput application
Juris Ormanis, Vladislavs Medvedevs, Jānis Judvaitis
International Conference on Embedded Wireless Systems and Networks (EWSN '23)
Kopsavilkums
Body Coupled Communication (BCC) technology has the potential to revolutionise the wearable device field by provid- ing substantial advantages in security, privacy and usability, yet understanding of the factors that influence signal path loss in BCC is crucial for developing accurate measurement techniques and refining the communication system. In this paper a new approach in proposed taking advantage of vary- ing signal loss on touch to enable user input detection and interpretation, it demonstrates high accuracy and reliability. This technology can potentially provide new opportunities for visually impaired or disabled individuals by designating specific body locations as scenario activation triggers and en- abling tactile and intuitive interaction with the technological environment. To study the impact of human touch on signal path loss multiple experiments were carried out and the find- ings enhance the understanding of the factors affecting BCC performance and provides an insight for further research.
Indeksēts Scopus / WoS · Scopus procentile: 35
