EDI — Elektronikas un datorzinātņu institūts
Back to staff

Didzis Lapsa

Mg. sc. ing.

Researcher

Didzis Lapsa is a researcher at the Institute of Electronics and Computer Science (EDI), where he began his work in November 2014 by joining the national research project KiFiS, contributing to the development of embedded systems and a wireless sensor node testbed. In 2018, he obtained a professional bachelor’s degree in Electrical Engineering from Riga Technical University, followed by a professional master’s degree in Electrical Engineering and Computer Science in 2019. Since 2020, he has been pursuing doctoral studies in Computer Science at the University of Latvia.

His main research directions include electrical engineering, embedded systems, sensor technologies, printed circuit board (PCB) design, measurement and instrumentation systems, energy consumption optimization in sensor nodes, as well as cyber-physical system solutions and physiological signal processing. His current scientific work is primarily focused on the development of efficient and reliable sensor systems, with particular attention to bioimpedance measurements for heart activity detection, signal processing, and the development of robust algorithms for physiological signal analysis.

Didzis has contributed to the development of the EDI WSN testbed (EDI TestBed), which has been widely used in research and international publications, and he has developed and co-authored several scientific papers in the fields of bioimpedance measurements and signal processing (including Sensors, Applied Sciences, and IEEE conference publications).

Outside of academic work, Didzis is passionate about technology popularization, maintaining a small educational YouTube channel, and engaging in electronics device repair and photo/video projects. In his free time, he is learning to play the guitar and pursues landscape photography as a hobby.

Projects

9 results

Publications

  • 2024

    PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review(opens in a new window)

    Didzis Lapsa, Rims Janeliukstis, Margus Metshein, Leo Selavo

    Applied Sciences, Vol. 14 (17), p. 7451, MDPI

    Abstract

    The monitoring of hemodynamic parameters, such as heart rate and blood pressure, provides valuable indications of overall cardiovascular health. It is preferable that such monitoring is non-invasive and in real time via an affordable, compact and small-scale device for maximum convenience. Numerous literature sources have exploited derivations of these parameters from photoplethysmogram (PPG) and electrical bioimpedance (EBI) signal measurements through the use of calculation algorithms of varying complexity. Compared to electrocardiogram (ECG), these measurement techniques have a merit of well-established practices of designing a wearable device that could conveniently be put on a wrist. The current paper provides a comprehensive review on the use of PPG and EBI measurement techniques in the context of hemodynamic parameter monitoring using a wearable device. A special emphasis is placed on the most basic hemodynamic parameter—heart rate—describing different algorithms of heart rate detection and monitoring. The last section provides an overview of commercially available and in-home wearable device technologies based on PPG and EBI measurements, their design challenges, and future prospects.

    Indexed in Scopus / WoS · Scopus percentile: 75

  • 2024

    Evaluation of Two-Electrode System Configurations for Forearm Arteries Bioimpedance Measurement(opens in a new window)

    Margus Metshein, Ksenija Pesti, Didzis Lapsa, Paul Annus, Rims Janeliukstis, Atis Elsts, Olev Martens

    2024 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), p. 1-6

    Abstract

    Pulse wave monitoring for hemodynamic parameter acquisition, including blood pressure, constitutes a challenge for wearable device development. Hypertension as a target for such development forms a global health issue. An important aspect is the connection to the object-electrode-skin interface-from which many problems in electrical measurements originate. Finite element model simulations and experimental measurements of forearm arteries' electrical bioimpedance have been presented in this paper to evaluate the two-electrode system compared to the four-electrode system in distal and perpendicular placement relative to the artery. The four-electrode system has been reported to provide higher pulsating blood volume proportions, reaching 0.09% from the total measured impedance in distal placement, while the two-electrode system exhibits lower values (0.05%). A strong positive correlation between the simulation and experimental results appeared in distal two-electrode placement (r=0.718), while the outcome is reversed in the perpendicular approach (r=-0.539). The experimented two-electrode system configurations are applicable in wearable device development but require further analysis for the perpendicular placement.

    Indexed in Scopus / WoS

  • 2024

    Signal Acquisition and Algorithm Design for Bioimpedance-Based Heart Rate Estimation from the Wrist(opens in a new window)

    Didzis Lapsa, Margus Metshein, Andrei Krivošei, Rims Janeliukstis, Olev Märtens, Atis Elsts

    Applied Sciences, Vol. 14 (21), p. 9632, MDPI

    Abstract

    Background: Heart rate (HR) is a critical biomarker that provides insights into overall health, stress levels, and the autonomic nervous system. Pulse wave signals contain valuable information about the cardiovascular system and heart status. However, signal acquisition in wearables poses challenges, particularly when using electrical sensors, due to factors like the distance from the heart, body movement, and suboptimal electrode placement. Methods: Electrical bioimpedance (EBI) measurements using bipolar and tetrapolar electrode systems were employed for pulse wave signal acquisition from the wrist in both perpendicular and distal configurations. Signal preprocessing techniques, including baseline removal via Hankel matrix methods, normalization, cross-correlation, and peak detection, were applied to improve signal quality. This study describes the combination of sensor-level signal acquisition and processing for accurate wearable HR estimation. Results: The bipolar system was shown to produce larger Δ𝑍(𝑡)ΔZ(t), while the tetrapolar system demonstrated higher sensitivity. Distal placement of the electrodes yielded greater Δ𝑍(𝑡)ΔZ(t) (up to 0.231 ΩΩ) when targeting both wrist arteries. Bandpass filtering resulted in a better signal-to-noise ratio (SNR), achieving 3.6 dB for the best bipolar setup and 4.8 dB for the tetrapolar setup, compared to 2.6 and 3.3 dB SNR, respectively, with the Savitzky–Golay filter. The custom HR estimation algorithm presented in this paper demonstrated improved accuracy over a reference method, achieving an average error of 1.8 beats per minute for the best bipolar setup, with a mean absolute percentage error (MAPE) of 8%. Conclusions: The analysis supports the feasibility of using bipolar electrode setups on the wrist and highlights the importance of electrode positioning relative to the arteries. The proposed signal processing method, featuring a preprocessing pipeline and HR estimation algorithm, provides a proof-of-concept demonstration for HR estimation from EBI signals acquired at the wrist.

    Indexed in Scopus / WoS · Scopus percentile: 75

  • 2023

    Wireless induction charging station for industrial application(opens in a new window)

    Pēteris Aizpurietis, Didzis Lapsa, Niklāvs Barkovskis, Arnis Salmiņš, Rims Janeliukštis, Kaspars Ozols

    2023 Workshop on Microwave Theory and Technology in Wireless Communications (MTTW), p. 62-66, IEEE

    Abstract

    Wiring for charging LiPo batteries poses problems due to electromagnetic interference and limitations of wire length. In this work, a method for charging wireless sensor network wirelessly using NRF52840 is developed for both transmitting and receiving side of equipment. A Qi-compliant WE760308103202 wireless charging coil receiver is used and its performance evaluated to estimate optimal parameters of wireless charging, such as load and resonance frequency detuning for receiver. By tuning the frequency of operation, it is possible to utilize generic electronic components with reduced costs.

    Indexed in Scopus / WoS

  • 2023

    Adaptive Signal-to-Noise Ratio Indicator for Wearable Bioimpedance Monitoring(opens in a new window)

    D. Lapsa, R. Janeliukstis, A. Elsts

    Sensors, Vol. 23 (20), p. 8532, MDPI

    Abstract

    Bioimpedance monitoring is an increasingly important non-invasive technique for assessing physiological parameters such as body composition, hydration levels, heart rate, and breathing. However, sensor signals obtained from real-world experimental conditions invariably contain noise, which can significantly degrade the reliability of the derived quantities. Therefore, it is crucial to evaluate the quality of measured signals to ensure accurate physiological parameter values. In this study, we present a novel wrist-worn wearable device for bioimpedance monitoring, and propose a method for estimating signal quality for sensor signals obtained on the device. The method is based on the continuous wavelet transform of the measured signal, identification of wavelet ridges, and assessment of their energy weighted by the ridge duration. We validate the algorithm using a small-scale experimental study with the wearable device, and explore the effects of variables such as window size and different skin/electrode coupling agents on signal quality and repeatability. In comparison with traditional wavelet-based signal denoising, the proposed method is more adaptive and achieves a comparable signal-to-noise ratio.

    Indexed in Scopus / WoS · Scopus percentile: 87

Patents

  • LR patent Nr. 15878 A

    A DEVICE AND METHOD FOR EVALUATION OF QUALITY OF BIOIMPEDANCE SIGNAL

    Description and link

    LR patent Nr. 15878 A, "A DEVICE AND METHOD FOR EVALUATION OF QUALITY OF BIOIMPEDANCE SIGNAL"

    View the patent on Espacenet(opens in a new window)
  • 2018 LR patents Nr. 15308

    Mobila ierīce bezvadu sensoru tīklu un to mezglu efektīvai izstrādei mērķa vide

    Inventors:Leo SEĻĀVO, Krišjānis NESENBERGS, Jānis JUDVAITIS, Didzis LAPSA, Rihards BALAŠS, Arnis SALMIŅŠ, Modris GREITĀNS

    Description and link

    LR patents Nr. 15308 “Mobila ierīce bezvadu sensoru tīklu un to mezglu efektīvai izstrādei mērķa vide”, Izgudrotāji Leo SEĻĀVO, Krišjānis NESENBERGS, Jānis JUDVAITIS, Didzis LAPSA, Rihards BALAŠS, Arnis SALMIŅŠ, Modris GREITĀNS, publicēts 20.03.2018.

    View the patent on Espacenet(opens in a new window)