EDI – Elektronikas un datorzinātņu institūts
Back to staff

Contact

Aleksejs Tatarinovs

Dr. sc. ing.

Senior Researcher

Alexey Tatarinov (Aleksejs Tatarinovs), PhD (Dr.Sc.Ing.), senior researcher at RTU and invited scientist in IECS with extensive experience in ultrasound applications, bone and muscle biomechanics, and materials testing. Post-graduate course “Mechanics of deformable solids”. Author of 40 scientific publications (H-factor = 12) and 3 patents. A researcher and PI in numerous projects funded by the Latvian Scientific Council (LZP), SBIR NIH (USA), SBIR NASA (USA), SBIR DoD (USA), European Space Agency, EU FP7, Horizon 2020, ARTEMIS, and others. Having been engaged for many years in bone studies using ultrasound, developing multi-frequency bone ultrasonometer, application of guided ultrasonic waves in NDT, and ultrasonic testing of muscles, he is the author of the BoMUS concept, fluent in the subject of research.

Projects

5 results

Publications

  • 2026

    Ultrasonic Monitoring of the Processes of Blast Freezing and Thawing of Meat(opens in a new window)

    Alexey Tatarinov 1 , Marija Osipova and Viktors Mironov

    Foods, Vol. 15, p. 328

    Abstract

    Freezing and thawing affect the structural integrity and quality of meat, yet these processes remain difficult to monitor due to spatial temperature gradients and non-uniform phase transitions. This study investigates the ability of ultrasound to detect dynamic freezing and thawing events in pork tissues with different fat contents. Specimens of water, lean meat, marbled meat, layered lean–fat structures, and lard were subjected to controlled freeze–thaw cycles while ultrasonic signals and internal temperatures were continuously monitored. Consistent amplitude drops in the megahertz range at entering the freezing phase formed characteristic signal patterns that differed sharply between lean and fatty tissues. Lean meat, dominated by water content, exhibited rapid signal loss at the onset of ice crystallization and a clear recovery of amplitude once fully frozen. Fat-rich tissues demonstrated prolonged attenuation and near disappearance of high-frequency signals, with incomplete recovery even at deep-frozen states. A jump of ultrasound velocity from 1.4–1.6 km/s in a warm state to 2.6–3.7 km/s in a frozen state indicated complete freezing. Hysteresis between temperature readings and actual phase transition moments was found. Distinct ultrasonic freeze–thaw signatures reflecting tissue composition suggest a novel approach for monitoring the true onset and completion of freezing and thawing in meat.

  • 2025

    Evaluation of Subcutaneous and Intermuscular Adipose Tissues by Application of Pattern Recognition and Neural Networks to Ultrasonic Data: A Model Study(opens in a new window)

    Alexey Tatarinov, Aleksandrs Sisojevs, Vladislavs Agarkovs and Jegors Lukjanovs

    Bioengineering, Vol. 12, p. 1373, MDPI

    Abstract

    Distinguishing subcutaneous adipose tissue (SAT) from intermuscular adipose tissue (IMAT) is clinically important because IMAT infiltration is strongly associated with age-related functional decline, sarcopenia, diabetes, cardiovascular disease, and obesity. Current assessments rely on MRI or CT, which are stationary, costly, and labor-intensive. Portable ultrasound-based solutions could enable broader, proactive screening. This model study investigated the feasibility of differentially assessing SAT and IMAT using features extracted from propagating ultrasound signals. Twenty-five phantoms were constructed using gelatin as a muscle-mimicking matrix and oil as the SAT and IMAT compartments, arranged to provide gradual variations in fat fractions ranging from 0% to 50%. Ultrasound measurements were collected at 0.8 MHz and 2.2 MHz, and multiple evaluation criteria were computed, including ultrasound velocity and parameters derived from the signal intensity. Classification domains were then generated from intersecting decision rules associated with these criteria. In parallel, artificial neural networks (ANN/LSTM) were trained and tested on identical phantom subsets to evaluate data-driven classification performance. Both the rule-based and ANN/LSTM approaches achieved diagnostically meaningful separation of SAT and IMAT. The aim of this work was to perform an experimental proof-of-concept study on idealized tissue models to demonstrate that ultrasound measurements can reliably differentiate SAT and IMAT, supporting the development of future screening devices.

  • 2025

    Evaluation of osteoporosis features in cortical bone models using pattern recognition methods applied to ultrasound data(opens in a new window)

    Alexey Tatarinov, Aleksandrs Sisojevs

    Ultrasonics, Vol. 158, Elsevier

    Abstract

    Cortical bone plays a crucial role in bone strength in the context of osteoporosis. Thinning of the cortex and intracortical porosity developing from the endosteum are the main independent indicators of osteoporosis-related fractures risk, which can be separately quantified by advanced imaging techniques. Numerous studies have shown the sensitivity of ultrasonic guided waves to changes in the thickness and porosity of cortical bone both in models and in human subjects. The present study demonstrates feasibility of the pattern recognition approach to separate determination of factors of diagnostic interest – cortical thickness (CTh) and intracortical porosity as the relative thickness of the porous layer (rPTh), where a set of guided waves velocities at different frequencies are used as evaluation criteria. The experiments were carried out on acrylic plastic plates as compact bone phantoms of different thicknesses with simulated pores in the form of CNC-drilled holes from below. The distance-time slopes of fast and slow wave packets at 250, 100 and 50 kHz were obtained as distance-time slopes in the corresponding spatiotemporal waveform profiles built by stepwise acquisition of ultrasonic signals. The evaluation criteria (distance-time slopes) in the training dataset formed the decision rules – 3-dimensional surfaces of the criterion distribution in the field CTh-rPTh. For the test object, the intersection of the segments of the probabilistic solution according to three decision rules gave the evaluation answer. The method allowed us to determine the values of both factors CTh and rPTh with reasonable diagnostic accuracy at different thicknesses of the covering soft tissues. The proposed approach can be adapted for the assessment of osteoporosis after obtaining an appropriate database in human studies.

    Indexed in Scopus / WoS · Scopus percentile: 89

  • 2025

    Properties Assessment of Perforated Metal Plates for Medical Use(opens in a new window)

    Marija Osipova, Viktors Mironovs, Antons Pacejs, Aleksejs Tatarinovs, Janis Lungevics, Vjaceslavs Zemcenkovs

    Conference Proceedings, Vol. 4, p. 265 - 269, RTU PRESS

    Abstract

    Thin-walled and sheet materials with regular through holes (perforation) have wide practical application in various fields, including in medicine for the manufacture of implants, trays for placing and storing cutting instruments, sterilization of consumables. Perforated metal materials (PMM), primarily made of titanium and stainless steel, are of the most attention to specialists in the field of medical engineering, since they are characterized by lower weight, high strength and biomechanical compatibility. The mechanical characteristics of PMM are determined by the initial properties of the material, the dimensions of the sheet or tape, the shape and total area of the perforation. If selected correctly, dimensions and area of the perforations can provide optimal flexibility and plasticity with a significant reduction in the weight of the implant. This paper presents properties of perforated plates made of stainless steel, obtained by non-destructive methods. In particular, the dependences of the Lamb wave velocities at different frequencies on the specific total area of the plate's perforation are shown. The data of elastic properties dependences on the perforation area. The data of microscopic studies of changes in the quality of holes obtained by laser cutting are also presented. © 2025 Elsevier B.V., All rights reserved.

  • 2025

    Evaluation of Factors-of-Interest in Muscle Phantoms Based on Ultrasonic Data(opens in a new window)

    Vladislavs Agarkovs, Aleksandrs Sisojevs, Aleksey M. Tatarinov and Tamāra Laimina

    IFMBE Proceedings, Vol. 131, p. 25 - 32, Springer Science and Business Media Deutschland GmbH

    Abstract

    Subcutaneous adipose tissue (SAT) and intermuscular adipose tissue (IMAT) are two forms of body fat. The differential assessment of SAT and IMAT contents in sarcopenia and obesity by ultrasonic measurements is difficult due to their complex influence. In the present study, the possibility of using pattern recognition methods applied to ultrasonic measurement data to discriminate SAT and IMAT values was investigated on muscle tissue mimicking phantoms. The muscle mimicking phantoms were made of gelatin (muscle) with oil (fat) layers (SAT) and inclusions (IMAT) with gradually varying SAT and IMAT contents from zero to 50% with a step 12.5%. The set included a net of 25 phantoms with five grades of SAT and IMAT, each varied independently. Each phantom (object under study) passed multiple repeatable ultrasound tests. For each object, a set of parameters was extracted from the set of ultrasonic signals, including speed of sound, ultrasound attenuation at two frequencies and signal amplitude integrals. Decision rules were constructed for all objects based on the set of the extracted parameters. The efficiency of the constructed rules was checked using the signals of the examination object. The results of the experiments demonstrated the potential effectiveness of the proposed approach for determining SAT and IMAT values separately. © 2025 Elsevier B.V., All rights reserved.